the
version A of our damper system is a combination of inroom adjustable damper with
aerosol inlet for efficiency check on the installed filter. This gives the opportunity
to change very easily the airflow (filter velocity) during checking with a velocity
meter from the clean room side. Furthermore, for DOP efficiency testing (at installed
filters) is an aerosol entry given to bring the test aerosol easily to the upstream
side of the filter media. Both are covered with a sealed screw to prevent any
leaks. The version B of our damper system gives a functional possibility of
simple low cost adjusting of the entering air volume. It means there is a bridge
attached to the collar that carries the dumper on a thread pin. Further more,
a :, gasket buffer prevents movements caused by the airflow. |