Type FAH 180/90
Certified to compliance with the Israeli Standard 4570 by the ISRAELI STANDATDS INSTITUTION and the ISRAELI CIVIL DEFENCE COMMAND
 
FEATURES
• NBC-Protection for 15 Persons (according to Israeli Standard)
• Applications in Standard shelters as nurseries, villas or command posts
 
Description Type FAH 180/90:

The NBC-Filtration System Type FAH 180/90 is a collective filtration system for airtight shelters and compartments, certified to supply 180 mVh (105 cfm) fresh air and 90 mVh (55 cfm) filtered air. The system provides filtered air in the case of NBC (Nuclear/Biological/ Chemical) warfare, or fresh air in the case of conventional warfare.

The system creates overpressure inside the protected area providing a safe and comfortable environment without the need for gas masks or protective clothing. The system is operated by normal electric power with manual backup in case of power failure.

 
Specifications are subject to change without prior notice
Certifications:
• Tested and certified by the Standards Institution of Israel and the Israeli Institute for Biological Research
• Approved by the Civil Defence Command
• CE - Hallmarks for Electrical Safety and EMI compliance
• Quality Control according to ISO 9001 and AQAP 120
 
SYSTEM FEATURES
• Additional performance capabilities for use in subtropical and tropical environment
• High blast protection according to the experiences of the Gulf War
• Manual backup in case of external power disruption
 
Installation Requirements:
1. Standard air tight shelter/ compartment
2. Air inlet: Standard 8" flange in an outer wall.
Center line: 1.90-2.10 m (75-85 inches) above the floor.
3. Air outlet: Standard 8" flange, located preferably opposite the air inlet.
 
Type FAH 480/180
Certified to compliance with the Israeli Standard 4570 by the ISRAELI STANDATDS INSTITUTION and the ISRAELI CIVIL DEFENCE COMMAND
 
FEATURES
• NBC-Protection for 30 Persons (according to Israeli Standard)
• A very common system for medium-sized shelters as in kindergartens etc.
 
Description Type FAH 480/180:

The NBC-Filtration System Type FAH 480/180 is a collective filtration system for airtight shelters and compartments, certified to supply 480 mVh (282 cfm) fresh air and 180 mVh (106 cfm) filtered air. The system provides filtered air in the case of NBC (Nuclear/Biological/ Chemical) warfare, or fresh air in the case of conventional warfare.

The system creates overpressure inside the protected area providing a safe and comfortable environment without the need for gas masks or protective clothing. The system is operated by normal electric power with manual backup in case of power failure.

 
Specifications are subject to change without prior notice
Certifications:
• Tested and certified by the Standards Institution of Israel and the Israeli Institute for Biological Research
• Approved by the Civil Defence Command
• CE - Hallmarks for Electrical Safety and EMI compliance
• Quality Control according to ISO 9001 and AQAP 120
 
SYSTEM FEATURES
• Additional performance capabilities for use in subtropical and tropical environment
• High blast protection according to the experiences of the Gulf War
• Manual backup in case of external power disruption
 
Installation Requirements:
1. Standard air tight shelter/ compartment
2. Air inlet: Standard 8" flange in an outer wall.
Center line: 1.90-2.10 m (75-85 inches) above the floor.
3. Air outlet: Standard 8" flange, located preferably opposite the air inlet.
 
 
 
Tasarım ve Yazılım : D&Z Dizayn 