| Overpressure
Blast Valve |
| |
| |
|
|
| |
| The Overpressure Blast Valve Type
A 3603 is a valve used to stop explosive blast waves from entering a bomb shelter
as well as to regulate the air pressure in the shelter. The valve is tested and
certified to the Israeli Standard 4570 by the Civil Defence Command and the Standards
Institution of Israel. |
| |
| The
Overpressure Blast Valve Type A 3603 is designed to release air from the shelter
while maintaining a constant overpressure and also to protect against explosive
and implosive blast waves. The valve is normally closed. It is maintenance-free
and withstands heat and corrosion. The springs are manufactured from special stainless
steel and all steel parts are phosphate treated and finished with a powder coating. |
| |
| Usage |
| Has to be installed inside the shelter
on a 14" flange according to BS 4504 - PN 6 or DIN 2501 - PN 6 |
| Should only be installed together with
"Noah's Ark" equipment manufactured by Beth-El Industries to ensure
maximum performance |
| |
| |
|
| |
|
|
| Certifications: |
|
Tested and certified to IS 4570 by the Standards Institution of Israel |
| Approved by the Civil Defence Command
of Israel |
| Quality
Control according to ISO 9001 |
|
Quality Assurance AQAP 120 |
| |
| |
| Specifications
are subject to change without prior notice |
| |
| |
| Overpressure
Blast Valve |
| |
| |
|
|
| |
| The Overpressure Blast Valve Type
A 7003 is a valve used to stop explosive blast waves from entering a bomb shelter
as well as to regulate the air pressure in the shelter. |
| |
| The
Overpressure Blast Valve Type A 7003 is designed to release air from the shelter
while maintaining a constant overpressure and also to protect against explosive
and implosive blast waves. The valve is normally closed. It is maintenance-free
and withstands heat and corrosion. The springs are manufactured from special stainless
steel and all steel parts are phosphate treated and finished with a powder coating. |
| |
| Usage |
| Has to be installed inside
the shelter on an 20" flange |
|
Should only be installed together with "Noah's Ark" equipment and accessories
manufactured by Beth-El Industries to ensure maximum performance |
| |
| |
|
| |
|
|
| Certifications: |
|
Quality Control according to ISO 9001 |
|
Quality Assurance AQAP 120 |
| |
| |
| Specifications
are subject to change without prior notice |
| |
| |
| Overpressure
Valve |
| |
| |
|
|
| |
| The Overpressure Valve Type Z 500
D is designed to regulate the differential pressure between the different areas
inside the shelter. The valve is normally closed. It conforms to the Israeli,
Singaporean and Swiss standards. The Valve is tested and certified by the Civil
Defence Command and the Standards Institution of Israel. |
| |
| The
Overpressure Valve Type Z 500 D is maintenance - free, temperature and corrosion
resistant. The differential pressure between rooms may be adjusted to the required
value. The valve must be installed only inside the protected area. |
| |
| Usage |
| Has to be installed between
the mainshelter and decontamination area/sanitary rooms. |
|
Has to be installed on an 8" flange according to BS 4504 - PN 6 or DIN 2501
- PN 6 |
| Should only be installed
together with "Noah's Ark" equipment manufactured by Beth-El Industries
to ensure maximum performance |
| |
| |
|
| |
|
|
| Certifications: |
|
Tested and certified to IS 4570 by the Standards Institution of Israel |
| Approved by the Civil Defence Command
of Israel |
| Quality
Control according to ISO 9001 |
|
Quality Assurance AQAP 120 |
| |
| |
| Specifications
are subject to change without prior notice |
| |
| |
| Overpressure
Valve |
| |
| |
|
|
| |
| The Overpressure Valve Type Z 600
is designed to regulate the differential pressure between the main shelter and
the decontamination area. The valve withstands pressures up to 50 kPa (7 psi).
The valve is tested and certified to the Israeli Standard 4570 by the Civil Defence
Command and the Standards Institution of Israel. |
| |
| The
Overpressure Valve Type Z 600 is maintenance - free, temperature and corrosion
resistant. The differential pressure between rooms may be adjusted to the required
value. The valve must be installed only inside the protected area. |
| |
| Usage |
| Has to be installed between
the mainshelter and decontamination area/sanitary rooms. |
|
Has to be installed on an 8" flange according to BS 4504 - PN 6 or DIN 2501
- PN 6 |
| Should only be installed
together with "Noah's Ark" equipment manufactured by Beth-El Industries
to ensure maximum performance |
| |
| |
|
| |
|
|
| Certifications: |
|
Tested and certified to IS 4570 by the Standards Institution of Israel |
| Approved by the Civil Defence Command
of Israel |
| Quality
Control according to ISO 9001 |
|
Quality Assurance AQAP 120 |
| |
| |
| Specifications
are subject to change without prior notice |
| |
| |
| Gas-tight
Shut-off Valve |
| |
| |
|
|
| |
|
|
| |
| With
achieved Excellency, the PPV Valves are a reliable solution to the requirement
of gas tight shut off valves in Bomb Shelters. The vulcanized rubber lining, light
weight body and long neck, all contribute to the manicured performance of the
Gas-tight Shut-off Valve. The smooth disc without pins of screws and the intensive
split shaft make operation smooth. |
| |
| Usage |
|
Available in a variety of different size |
|
Should only be installed together with "Noah's Ark" equipment manufactured
by Beth-El Industries to ensure maximum performance |
| |
| Level operated |
with actuator | |
|
|
|
| |
|
|
| |
| |
| |
| |
| Differential Pressure Gauge |
| |
| |
|
|
| |
|
The Differential Pressure Gauge Type DPG-A shows the differential pressure
between two rooms. It is used in shelters to indicate the overpressure disparity
between the shelter and the outside area, or the differential pressure between
the different areas inside the shelter. Selected for its high accuracy,
the cost effective Differential Pressure Gauge Type DPG-A, is guaranteed to be
accurate within 2% (of full scale) suiting precise needs. Low air pressure, positive,
negative (vacuum) or differential, are quickly indicated on an analog display,
using simple frictionless movement. It is designed to resist shock, vibration
and overpressures. The Differential Pressure Gauge withstands a blast pressure
of 40 bar at an impulse of 70 bar ms. It has no manometer fluid, alleviating
the problems of fluid evaporation, freezing, toxicity of leveling difficultise. Tested
and certified for compliance to the Israeli and Singaporean Standards. |
| |
| Usage |
| Should only be installed together
with "Noah's Ark" equipment manufactured by Beth-El Industries to ensure
maximum performance |
|
Variety of ranges available |
| |
| |
|
| |
|
|
| Certifications: |
|
Tested and certified for compliance to the applicable Israeli, Singaporean and
Swiss Standards. |
| Quality Control
according to ISO 9001 and AQAP 120 |
| |
 |
| |
 |
|
| |